V8/XV8/XH8, V7/XV7/XH7, V6/XV6/XH6 Diagnostic Ultrasound System
Samsung Medison Co., Ltd. • Radiology • 06/21/2024
Device Purpose
The V8/XV8/XH8, V7/XV7/XH7, V6/XV6/XH6 Diagnostic Ultrasound System is engineered to deliver comprehensive multi-modal ultrasound imaging and body fluid analysis for diverse clinical diagnostics. It integrates established ultrasound technology with advanced AI-driven NerveTrack for enhanced anatomical delineation and SonoSync for remote collaboration, aiming to improve diagnostic precision and clinical utility.
Summary
The Samsung Medison V8/XV8/XH8, V7/XV7/XH7, V6/XV6/XH6 Diagnostic Ultrasound System is a mobile, software-controlled device intended for general-purpose diagnostic ultrasound imaging and body fluid analysis. It acquires and displays ultrasound data using a comprehensive range of imaging modes, including 2D, Color Doppler, Power Doppler, M-mode, Pulsed and Continuous Wave Doppler, Tissue Doppler Imaging and Wave, ElastoScan, 3D/4D, and combined/multi-image modes. The system is designed for use by qualified healthcare professionals across a wide spectrum of clinical applications such as Fetal/Obstetrics, Abdominal, Gynecology, Cardiac (Adult and Pediatric), Muscular-Skeletal, Urology, and Peripheral Vessel imaging, providing tools for anatomical measurements and diagnostic analysis in various healthcare environments. This iteration of the system introduces significant enhancements, including the expanded application of AI-powered NerveTrack Segmentation for improved identification and contour mapping of twelve nerve types and nine surrounding anatomical structures. It incorporates a new TA2-9 transducer, a 27-inch OLED monitor for superior image visualization, and an updated SonoSync feature for remote diagnostic image viewing and review. Non-clinical testing validated the AI's performance, with NerveTrack demonstrating high accuracy (approximately 90.3% for detection and 98.42% for segmentation) and speed, maintaining robustness across various BMI subgroups. The system also features real-time display of mechanical and thermal indices to ensure patient safety during examinations.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the performance of the AI-driven NerveTrack segmentation vary across the twelve different nerve types, particularly in challenging patient anatomies or pathologies?; What specific improvements in image resolution or diagnostic confidence are attributable to the new TA2-9 transducer and the 27-inch OLED monitor, especially in deeper tissue imaging?; What are the bandwidth and latency requirements for optimal performance of the SonoSync remote viewing and review feature, and how does it handle potential network interruptions?; How was the ground truth for NerveTrack's contour segmentation of surrounding structures (bone, blood vessel, muscle, ligament) validated for accuracy across different tissue densities and patient variability?; Are there any comparative studies or data demonstrating the clinical impact of NerveTrack on procedure time, accuracy, or patient outcomes in nerve-related interventions?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Qualifies as a cyber device under §524B (post-Dec 2023, networked)
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly