qCT LN Quant

Qure.ai Technologies • Radiology • 08/16/2024

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

qCT LN Quant is a software device utilizing deep learning to provide quantitative characterization, including volumetric and diameter measurements, of user-identified solid pulmonary nodules from CT scans. Its methodology involves semi-automatic, user-assisted segmentation and integrates decision support tools like the Brock Score and Lung-RADS calculators to aid clinicians in the assessment and tracking of these nodules.

Summary

The qCT LN Quant is a software device designed for the tracking, assessment, and quantitative characterization of user-detected solid pulmonary nodules (≥ 6mm) from non-contrast chest CT scans. Its core methodology involves a deep-learning algorithm that processes these scans after a user performs semi-automatic segmentation of nodules using double seed points, with options for interactive fine-tuning of boundaries. The system provides volumetric and diameter measurements, alongside computer analysis based on morphological characteristics, either for a single study or longitudinally across several thoracic studies. Results, including 2D and 3D reconstructed views of nodules with their respective measurements, can be integrated into existing workflows via PACS as a secondary capture series or viewed on a dedicated web application. The device is intended for use by trained medical specialists such as radiologists and pulmonologists. Key quantitative outputs include average diameter and volume, with additional features such as long and short axis diameters, effective diameter, Mean/Minimum/Maximum Hounsfield Units (HU), volume change over time, and Volume Doubling Time (VDT). The software also incorporates a Brock Score - Risk Calculator, which uses the device-measured nodule diameter and clinician-provided inputs to estimate malignancy probability, and a Lung-RADS™ calculator based on ACR guidelines to assist in decision-making. Furthermore, it can provide recommendations based on Fleischner Society guidelines. Clinical performance testing on 216 solid nodules demonstrated median absolute normalized errors of 11.1% for long axis diameter, 14.3% for short axis diameter, and 20.7% for volume. The device is explicitly not intended for clinical diagnosis or to replace a full patient evaluation but serves as an informational tool.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Pulmonary noduleCT scanQuantitative characterizationDeep learningImage processingNodule segmentationVolumetric analysisDiameter measurementBrock ScoreLung-RADS

Device Metadata

Submission Number
K240740
Company
Qure.ai Technologies
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the semi-automatic segmentation process using double seed points compare in terms of user time and accuracy to fully automated or purely manual segmentation methods for pulmonary nodules?; What is the impact of variability in CT acquisition parameters (e.g., slice thickness, reconstruction kernel) on the accuracy of the qCT LN Quant's quantitative measurements, especially for volume doubling time calculations?; How was the deep learning algorithm trained and validated, particularly concerning the diversity of nodule morphologies and patient populations, to ensure robustness and minimize bias beyond the provided study of 216 nodules?; Could the integration of the Brock Score and Lung-RADS calculators within the software potentially influence clinician decision-making, and are there studies planned or underway to evaluate this impact on patient management pathways and outcomes?; What are the specific performance characteristics of the qCT LN Quant when analyzing nodules at the lower limit of its indicated size (≥ 6mm) or those with subtle morphological features?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, bias)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
qCT LN Quant - Qure.ai Technologies | ESL FDA AI Device Intelligence