Device Purpose
MICSI-RMT is a software medical device designed to enhance head MRI images by reducing noise in both functional (fMRI) and diffusion (dMRI) datasets. It employs a Principal Component Analysis (PCA) based algorithm to process DICOM images, aiming to improve image quality, signal-to-noise ratio, and the precision of derived parametric maps for neuroradiological assessment.
Summary
MICSI-RMT is a Software as a Medical Device (SaMD) designed for enhancing magnetic resonance imaging (MRI) images, specifically by reducing image noise for head MRI. The software processes both functional MRI (fMRI) and diffusion MRI (dMRI) images that are DICOM 3.0 compliant. It operates without a direct user interface; DICOM images from an MRI scanner are routed through a DICOM router and processor (Mercure), where MICSI-RMT applies its denoising algorithm. For dMRI images, the device uses Diffusion Tensor Imaging (DTI) to perform parameter estimation after denoising. The processed images, along with the originals, are then sent to a PACS system for review by radiologists. The core of its image enhancement capability relies on a Principal Component Analysis (PCA) based algorithm. The performance of MICSI-RMT was validated through a retrospective rater study comparing its processed images against standard of care (SOC) processed images. Qualitative assessments by expert neuroradiologists indicated that MICSI-RMT enhanced images achieved Likert scores greater than 3 for both overall image quality (ability to visualize small brain structures, adequate contrast) and artifact presence (no artificial blurring or occluding noise). Quantitative metrics demonstrated significant improvements: signal-to-noise ratio (SNR) in white matter increased by 5% or more. For fMRI, activation maps in Broca’s and Wernicke’s regions showed improved median z-scores (Broca's: 3.01 to 3.64; Wernicke's: 2.80 to 3.41), indicating stronger confidence in neural activity detection. For dMRI, the standard deviation of mean diffusivity (MD) and fractional anisotropy (FA) in the posterior limb of the internal capsule was reduced (MD: 0.16 to 0.075; FA: 0.09 to 0.069), signifying more precise parametric maps.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the Principal Component Analysis (PCA) algorithm used in MICSI-RMT specifically differentiate signal from noise in fMRI and dMRI datasets compared to other statistical denoising techniques?; What is the computational time required for MICSI-RMT to process typical head fMRI and dMRI datasets, and how does this integrate into a high-throughput clinical radiology workflow?; Were any specific patient populations or neurological conditions underrepresented in the retrospective rater study, and how might their unique image characteristics affect MICSI-RMT's performance?; Beyond the observed improvements in SNR and z-scores, what is the quantifiable impact of MICSI-RMT on diagnostic confidence or clinical decision-making in neuroradiology?; How does the performance of MICSI-RMT's PCA-based denoising compare to deep learning-based methods, particularly in terms of preserving subtle pathological features or avoiding the introduction of algorithm-specific artifacts?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, HBOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?