uCT 550

Shanghai United Imaging Healthcare Co., Ltd. • Radiology • 01/14/2025

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The uCT 550 is a Class II Computed Tomography X-ray system designed to generate cross-sectional body images using computer reconstruction of X-ray transmission data. Its efficacy and safety, including enhanced image quality and dose reduction through the DELTA (Deep Recon) algorithm, were established through bench and clinical evaluations, leading to a determination of substantial equivalence to predicate devices.

Summary

The uCT 550, a Class II Computed Tomography (CT) X-ray system developed by Shanghai United Imaging Healthcare Co., Ltd., has received regulatory clearance. This device is specifically engineered to produce detailed cross-sectional images of the human body by employing computer reconstruction techniques on acquired X-ray transmission data. Its approval stems from a determination of substantial equivalence to other CT systems already legally marketed, affirming its intended use for diagnostic imaging. Supporting its marketing authorization, the uCT 550 underwent comprehensive performance evaluations, encompassing both bench and clinical studies. These assessments particularly highlighted the efficacy of its proprietary DELTA (Deep Recon) algorithm, which demonstrated improvements in image quality while simultaneously contributing to dose reduction. Adherence to a multitude of safety and quality standards further substantiated the conclusion that the uCT 550 possesses a safety and effectiveness profile comparable to its predicate devices, although its continued market presence remains contingent upon ongoing compliance with regulatory requirements such as annual registration, device listing, and good manufacturing practices.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

uCT 550Computed TomographyX-ray systemClass II medical deviceSubstantial equivalenceDELTA (Deep Recon) algorithmImage qualityDose reductionRegulatory controlsPremarket submission

Device Metadata

Submission Number
K241166
Company
Shanghai United Imaging Healthcare Co., Ltd.
Panel
Radiology
Product Code
N/A
Data Type
N/A
Clinical Function
N/A
AI Function
N/A
AI Subclass
N/A

Relevant Clinical Questions

  • Q1. How does the DELTA (Deep Recon) algorithm specifically achieve both improved image quality and dose reduction compared to conventional reconstruction methods?; What were the specific clinical evaluation protocols and patient cohorts used to demonstrate the uCT 550's safety and effectiveness profile?; Beyond substantial equivalence, are there any unique technical specifications or features of the uCT 550 that differentiate it from its predicate devices?; What long-term post-market surveillance data is planned or being collected to monitor the uCT 550's performance, particularly regarding image artifact reduction and dose optimization in routine clinical use?; What are the specific thresholds or criteria for device changes that would necessitate a new premarket submission for the uCT 550?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score20/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
uCT 550 - Shanghai United Imaging Healthcare Co., Ltd. | ESL FDA AI Device Intelligence