Ibex Medical Analytics Ltd. • Pathology • 01/24/2025

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Galen™ Second Read™ software device aims to enhance prostate cancer detection by providing an adjunctive AI-powered "second read" on digitized biopsy slides, specifically highlighting suspicious areas in cases initially diagnosed as benign. It utilizes image analysis of H&E stained whole slide images to identify tissue morphology indicative of prostate adenocarcinoma, demonstrating improved pathologist sensitivity for cancer detection through a machine learning-based approach.

Summary

Ibex Medical Analytics Ltd. has received authorization to market its Galen™ Second Read™ software device. This software is designed to analyze scanned whole slide images from prostate core needle biopsies, specifically those prepared from hematoxylin & eosin stained formalin-fixed paraffin embedded tissue. Its primary function is to identify cases initially diagnosed as benign that warrant further review by a pathologist, providing case- and slide-level alerts, including a heatmap to highlight areas likely containing cancer, when suspicious tissue morphology for prostate adenocarcinoma is detected. The Galen™ Second Read™ is intended as an adjunctive tool for pathologists, and its outputs are not for standalone diagnosis. Performance validation demonstrated the device's precision in identifying and accurately localizing suspicious tissue areas. Clinical studies indicated that the software can effectively identify prostate cancer cases, including those potentially missed by standard of care. Pathologists using the device showed a statistically significant improvement in sensitivity for cancer detection, especially for cases initially assessed as benign, while experiencing a manageable decrease in specificity. The device's characteristics were found to be substantially equivalent to an existing product, Paige Prostate, with its differences not raising new safety or effectiveness concerns.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Prostate cancerWhole slide imagingPathologyArtificial intelligenceSecond ReadBiopsyHematoxylin & EosinSensitivitySpecificityDigital pathology

Device Metadata

Submission Number
K241232
Company
Ibex Medical Analytics Ltd.
Panel
Pathology
Product Code
N/A
Data Type
N/A
Clinical Function
N/A
AI Function
N/A
AI Subclass
N/A

Relevant Clinical Questions

  • Q1. How does the Galen™ Second Read™ algorithm specifically identify "suspicious tissue morphology" for prostate adenocarcinoma, and what are its limitations regarding subtle or rare cancer variants?; What is the false positive rate (decrease in specificity) observed with the Galen™ Second Read™ in a real-world clinical setting, and how does it impact pathologist workflow and diagnostic confidence?; Are there specific types of prostate cancer cases (e.g., low-grade, multifocal, or those with confounding artifacts) where the Galen™ Second Read™ demonstrates a greater or lesser improvement in sensitivity compared to standard practice?; What are the long-term implications and potential for over-diagnosis or increased biopsy rates if the Galen™ Second Read™ becomes widely adopted, given its focus on identifying potentially missed benign cases for further review?; How does the performance of Galen™ Second Read™ compare quantitatively with Paige Prostate or other similar AI-powered diagnostic tools across various patient demographics or biopsy types?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score25/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials(embedded)
✓ Detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, HBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Galen™ Second Read™ - Ibex Medical Analytics Ltd. | ESL FDA AI Device Intelligence