SubtleSYNTH (1.x)

Subtle Medical, Inc. • Radiology • 07/11/2024

510(k)IEC 62304 Class B§524B Cyber Device
FDA Summary PDF

Device Purpose

SubtleSYNTH (1.x) is a machine learning-based software device that synthesizes STIR-equivalent MR images of the spine from existing T1-weighted and T2-weighted sequences. Its methodology relies on a convolutional neural network to generate these SynthSTIR images, which have demonstrated interchangeability with conventionally acquired STIR images in non-clinical and reader-based studies.

Summary

SubtleSYNTH (1.x) is a software-as-a-medical-device designed for post-processing Magnetic Resonance (MR) images of the spine. Its core function is to synthesize a STIR-like contrast image, termed SynthSTIR, using a machine learning algorithm, specifically a convolutional neural network (CNN). The software operates by taking previously acquired T1-weighted and T2-weighted spine MR images as input. It processes these images in the background, without direct interaction with the MR scanner or a user interface, to generate the SynthSTIR image. This synthesized image is then transmitted via a compatible Medical Device Data System (MDDS) to a Picture Archiving and Communication System (PACS) or other DICOM node for clinical review by radiologists. SubtleSYNTH is intended to be used in imaging centers, clinics, or hospitals, and can operate within a facility's network or remotely, depending on the MDDS configuration, while the device itself is not networked. The performance of SubtleSYNTH was validated through comprehensive non-clinical testing and two key interchangeability studies. Quantitative bench testing on 80 diverse clinical spine MR studies demonstrated that SynthSTIR images maintained consistent relative tissue contrasts compared to acquired STIR images, with a low Root Mean Square Error (0.39) and high cosine similarity (>0.9). Bland-Altman analysis showed no significant bias in pixel values for key tissues (Bone, Disc, CSF, Spinal Cord, Fat). The two interchangeability studies involved radiologists classifying 104 spine cases, presented as either SynthSTIR or acquired STIR images, across various pathologies. Both studies, one presenting only STIR/SynthSTIR (Study A) and the other including additional standard sequences (Study B), successfully met their primary endpoint. The results, analyzed using Generalized Linear Mixed Models and bootstrap methods, indicated low interchangeability percentages (Study A: ~2.1%; Study B: ~0.6%), well within the predefined 10% margin, confirming that SynthSTIR images are interchangeable with traditionally acquired STIR images for diagnostic interpretation across different pathologies and scanner types. The training dataset for the CNN comprised 424 distinct cases, separate from the testing datasets.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

MRISpine ImagingSTIR ContrastImage SynthesisMachine LearningConvolutional Neural Network (CNN)T1-weightedT2-weightedPost-processing SoftwareImage Interchangeability

Device Metadata

Submission Number
K241329
Company
Subtle Medical, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation
AI Subclass
synthetic data generation

Relevant Clinical Questions

  • Q1. How does the performance of SubtleSYNTH's SynthSTIR vary across different MRI field strengths (e.g., 0.3T vs. 1.5T vs. 3T) specifically for subtle pathological findings in the spine?; What is the impact on diagnostic confidence and interpretation time for radiologists when using SynthSTIR images compared to conventionally acquired STIR images, particularly in complex cases with multiple pathologies?; Given that the training data's ethnicity is inferred, what steps could be taken to prospectively ensure and validate performance robustness across diverse ethnic populations, and how sensitive is the algorithm to variations not captured in the current demographic inferences?; How does SubtleSYNTH's CNN architecture specifically address potential artifacts or noise amplification that might occur when synthesizing STIR contrast from T1w and T2w images with varying initial quality?; Beyond interchangeability in image classification, what are the quantitative differences in specific measurements (e.g., lesion size, signal intensity ratios for specific tissues beyond the five tested) between SynthSTIR and acquired STIR images, and are these differences clinically significant?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Qualifies as a cyber device under §524B (post-Dec 2023, networked)

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score15/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, machine learning, neural network, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(remote, network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(configuration)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly