VUNO Med-Chest X-ray Triage/VUNO Med-CXR Link Triage
Vuno Inc. • Radiology • 11/15/2024
Device Purpose
VUNO Med-Chest X-ray Triage is a Class II radiological software designed to enhance clinical workflow efficiency by using artificial intelligence for computer-assisted triage and notification of suspected critical findings like pleural effusion and pneumothorax. It employs a convolutional neural network (CNN) algorithm to analyze adult chest X-ray images, providing case-level output for worklist prioritization, with demonstrated high accuracy (ROC AUC > 0.95) in classifying these conditions, affirming its substantial equivalence to existing technology.
Summary
VUNO Med-Chest X-ray Triage/VUNO Med-CXR Link Triage is a Class II radiological software designed for computer-assisted triage and notification. This artificial intelligence-powered tool analyzes adult chest X-ray images to identify the presence of suspected critical findings, specifically pleural effusion and pneumothorax. It employs a convolutional neural network (CNN) algorithm to analyze images for features suggestive of these conditions, providing case-level output for worklist prioritization within the Picture Archive and Communications Systems (PACS) or workstation. The software functions as a passive notification tool, intended solely for prioritization within standard clinical workflow, and does not send proactive alerts directly to medical specialists. Its results are not meant for standalone clinical decision-making or to highlight anomalies other than pleural effusion or pneumothorax. Evaluation of the software, including clinical performance tests, demonstrated high accuracy in classifying both pneumothorax (ROC AUC > 0.95) and pleural effusion (ROC AUC > 0.95), with robust performance across diverse conditions. The review concluded that the software is substantially equivalent to existing technology, presenting no new fundamental scientific approaches or additional safety and effectiveness risks.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific clinical scenarios or patient populations would benefit most from the worklist prioritization provided by VUNO Med-CXR Triage?; How does the software's performance (ROC AUC > 0.95) translate into practical clinical impact, such as reduced diagnostic delays or improved patient outcomes for pleural effusion and pneumothorax?; Given its passive notification role, what are the potential workflow integration challenges or benefits for radiology departments adopting this AI tool?; Are there any known limitations or specific types of chest X-ray images (e.g., specific pathologies, image quality issues) where the software's accuracy might be compromised?; What are the plans for future iterations or expansions of the software's capabilities beyond pleural effusion and pneumothorax detection, and how would these be validated?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Qualifies as a cyber device under §524B (post-Dec 2023, networked)
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.