ChestView US
Gleamer SAS • Radiology • 02/27/2025
Device Purpose
The ChestView US device is a Class II Medical Image Analyzer and Computer-Assisted Detection (CADe) software designed to aid radiologists and emergency medicine physicians in identifying abnormalities on frontal and lateral chest radiographs. It leverages machine learning to analyze images, marking regions of interest and demonstrating high accuracy and improved diagnostic performance in clinical studies, serving as a concurrent reading aid without replacing professional judgment.
Summary
A company received communication on February 27, 2025, regarding its ChestView US device, which has been identified as a Class II Medical Image Analyzer. Following a review of the device's premarket submission, it was determined to be substantially equivalent to existing, legally marketed devices for its specified indications for use. This determination allows the device to be marketed, subject to standard general market controls, including requirements for annual registration, device listing, good manufacturing practices, and labeling.ChestView US is a radiological Computer-Assisted Detection (CADe) software designed to analyze frontal and lateral chest radiographs. Utilizing machine learning, it identifies and marks regions of interest such as nodules, pleural space abnormalities, mediastinum/hila abnormalities, and consolidations. The device is intended as a concurrent reading aid for radiologists and emergency medicine physicians, supplementing but not replacing their professional judgment or other diagnostic testing. Performance data from standalone and clinical studies demonstrated high accuracy and improved diagnostic performance for users when aided by the device, confirming its safety and effectiveness relative to comparable technology.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific machine learning algorithms does ChestView US employ, and how do they handle edge cases or atypical presentations of abnormalities?; How does the device's performance vary across different patient demographics or image acquisition protocols (e.g., portable versus fixed X-ray machines)?; What are the false positive and false negative rates for each identified region of interest (nodules, pleural space, mediastinum/hila, consolidations), and how do these impact clinical workflow?; Are there any known limitations or scenarios where the device's performance degrades, and what mitigation strategies are recommended for clinicians?; What ongoing post-market surveillance or validation studies are planned to monitor the device's long-term performance and impact on patient outcomes in real-world clinical settings?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly