Medscape Medical NewsAll articles

6450 Ultrasound System (MyLabE80); 6450 Ultrasound System (MyLabE85)

Esaote S.p.A. • Radiology • 05/16/2025

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Esaote 6450 Ultrasound System, including MyLabE80 and MyLabE85 models, is a general-purpose diagnostic ultrasound system designed for various medical imaging applications. Its substantial equivalence to legally marketed devices was affirmed through comprehensive non-clinical testing of acoustic output, biocompatibility, and safety standards, incorporating new features like the XStrain LA for advanced left atrium analysis and the IHX 6-25 probe.

Summary

A communication from the U.S. Food & Drug Administration dated May 16, 2025, informed Esaote S.p.A. of the successful review of their 6450 Ultrasound System, which encompasses the MyLabE80 and MyLabE85 models. This Class II Ultrasonic Pulsed Doppler Imaging System was determined to be substantially equivalent to existing legally marketed predicate devices for its specified indications for use. Consequently, Esaote S.p.A. has been authorized to market the device, contingent upon adherence to general control provisions, including annual registration, device listing, good manufacturing practices, and appropriate labeling. The 6450 Ultrasound System is designed as a general-purpose diagnostic ultrasound platform, with the MyLabE80 and MyLabE85 models primarily differentiated by their license configurations. Key new features integrated into the system include XStrain LA, an advanced processing package tailored for Left Atrium analysis, and a new IHX 6-25 probe. The system's safety and performance were comprehensively assessed through various non-clinical tests, covering aspects such as acoustic output, biocompatibility, cleaning and disinfection efficacy, and compliance with thermal, electrical, electromagnetic, and mechanical safety standards. These evaluations confirmed the device's conformity with applicable medical device safety and performance standards, eliminating the need for clinical studies to support the substantial equivalence determination.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

FDAEsaote S.p.A.Ultrasound SystemMyLabE80MyLabE85Substantial EquivalenceDiagnostic ImagingXStrain LANon-clinical testsMedical Device Safety

Device Metadata

Submission Number
K241671
Company
Esaote S.p.A.
Panel
Radiology
Product Code
N/A
Data Type
N/A
Clinical Function
N/A
AI Function
N/A
AI Subclass
N/A

Relevant Clinical Questions

  • Q1. What specific clinical benefits does the new XStrain LA advanced processing package offer for Left Atrium analysis compared to previous methods or devices?; How does the IHX 6-25 probe enhance diagnostic capabilities or patient comfort compared to other probes available for the system?; Given that no clinical studies were required, what were the most critical non-clinical test results that strongly supported the substantial equivalence determination for this system?; Are there any specific patient populations or clinical applications where the 6450 Ultrasound System, particularly with its new features, demonstrates a notable advantage?; What are the long-term data collection plans, if any, for post-market surveillance of the 6450 Ultrasound System regarding its performance and safety in real-world clinical settings?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(labeling)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(configuration)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
6450 Ultrasound System (MyLabE80); 6450 Ultrasound System (MyLabE85) - Esaote S.p.A. | ESL FDA AI Device Intelligence