Medscape Medical NewsAll articles

TriVerity

Inflammatix, Inc. • Microbiology • 01/10/2025

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The TriVerity test is an automated in vitro diagnostic system designed to measure host response gene expression via RT-LAMP technology. It aims to differentiate bacterial, viral, and non-infectious illness, and to predict severe outcomes in patients with suspected acute infection or sepsis.

Summary

The TriVerity test, developed by Inflammatix, Inc., is an automated, semi-quantitative in vitro diagnostic system designed to measure the relative expression levels of host response genes in RNA isolated from whole blood. Utilizing reverse transcription loop-mediated isothermal amplification (RT-LAMP) on the Myrna instrument, it generates three distinct scores, each falling into one of five interpretation bands. These scores aid in differentiating bacterial infections, viral infections, and non-infectious illness, and in determining the likelihood of 7-day need for mechanical ventilation, vasopressors, and/or renal replacement therapy in adult patients presenting with suspected acute infection or sepsis. This system has been determined to be substantially equivalent to legally marketed predicate devices, allowing its marketing. Extensive analytical and clinical studies were conducted to evaluate the TriVerity test's performance. Analytical validation demonstrated robust reproducibility, specimen and reagent stability, linearity across its dynamic range, and high analytical sensitivity, with no significant interference or cross-reactivity observed. A prospective, multi-center clinical study involving over a thousand participants showed high accuracy for diagnosing bacterial and viral infections (AUROCs of 0.83 and 0.91, respectively, with consensus adjudication) and for predicting severe illness (AUROC 0.78). The test demonstrated superior accuracy compared to common biomarkers like Procalcitonin (PCT), C-Reactive Protein (CRP), and White Blood Cells (WBC), and its performance remained consistent across diverse racial and immune status groups, enhancing risk stratification for severe outcomes.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

TriVerity testHost response genesRT-LAMPIn vitro diagnosticBacterial infectionsViral infectionsSepsisPrognosticClinical studyAUROC

Device Metadata

Submission Number
K241676
Company
Inflammatix, Inc.
Panel
Microbiology
Product Code
N/A
Data Type
N/A
Clinical Function
N/A
AI Function
N/A
AI Subclass
N/A

Relevant Clinical Questions

  • Q1. What specific host response genes are measured by the TriVerity test, and what is the biological rationale for their selection in differentiating infection types and predicting severity?; How do the "three distinct scores" translate into the "five interpretation bands," and what specific clinical actions or decisions are recommended for each band?; What was the consensus adjudication process for confirming bacterial and viral infections in the clinical study, and how might different adjudication methods impact the reported AUROCs?; Beyond AUROCs, what are the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the TriVerity test for both diagnostic and prognostic indications, especially in low and high prevalence settings?; Are there specific patient cohorts (e.g., immunocompromised, pediatric, specific pathogen types) where the TriVerity test's performance might differ, and what further studies are planned or needed to assess this?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score0/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials
- Not detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, ML-BOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
TriVerity - Inflammatix, Inc. | ESL FDA AI Device Intelligence