Medscape Medical NewsAll articles

NeuroICH

Neurocareai Inc. • Radiology • 11/07/2024

510(k)IEC 62304 Class B§524B Cyber Device
FDA Summary PDF

Device Purpose

Neurocareai Inc.'s NeuroICH is an AI-powered radiological computer-aided triage and notification tool designed to rapidly identify suspected intracranial hemorrhage (ICH) from non-contrast head CT images. It employs a deep learning algorithm to analyze images in parallel with standard interpretation, demonstrating high sensitivity and specificity in retrospective studies, aiming to expedite specialist involvement through quick notifications.

Summary

Neurocareai Inc.'s NeuroICH is a software-based radiological computer-aided triage and notification tool, leveraging an artificial intelligence algorithm to analyze non-contrast head CT images for findings suggestive of intracranial hemorrhage (ICH). It functions in parallel with standard image interpretation to identify suspected ICH cases and automatically sends notifications, including non-diagnostic preview images, to appropriate specialists. The device is intended solely for informational purposes, aiding in streamlined communication and earlier specialist involvement, rather than serving as a diagnostic tool, with final diagnostic and care decisions remaining the responsibility of trained clinicians based on high-quality diagnostic images. The NeuroICH device utilizes deep learning AI algorithms, similar to the legally marketed predicate device Viz ICH, and offers mobile application interfaces for notifications without altering original medical images or disrupting standard hospital workflows. Performance data from a retrospective study demonstrated its effectiveness, achieving a sensitivity of 94.81% and a specificity of 92.53% in identifying ICH cases. Furthermore, the average time to notification was exceptionally fast at 0.37 0.20 minutes, significantly accelerating specialist awareness compared to traditional processes and underscoring its potential to enhance the timely identification and management of critical patients.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

NeuroICHIntracranial HemorrhageArtificial IntelligenceNon-contrast CTRadiological triageNotification toolDeep learningSensitivitySpecificityClinical workflow

Device Metadata

Submission Number
K241719
Company
Neurocareai Inc.
Panel
Radiology
Product Code
N/A
Data Type
N/A
Clinical Function
N/A
AI Function
N/A
AI Subclass
N/A

Relevant Clinical Questions

  • Q1. How does the NeuroICH device's AI algorithm perform in detecting subtle or atypical intracranial hemorrhages, and what are its specific limitations in such scenarios?; What real-world impact does the rapid notification feature have on patient outcomes, particularly regarding time to intervention or neurological recovery, beyond the observed time savings?; Are there specific patient demographics or imaging characteristics (e.g., artifacts, scan quality) that might affect the NeuroICH device's reported sensitivity and specificity?; What mechanisms are in place for the NeuroICH device to continuously learn and update its AI algorithm, ensuring sustained or improved performance over time?; How does the integration of NeuroICH affect the cognitive load or diagnostic responsibilities of clinicians, given its non-diagnostic informational purpose?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Qualifies as a cyber device under §524B (post-Dec 2023, networked)

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score20/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly