Medscape Medical NewsAll articles

Prostate MR AI (VA10A)

Siemens Healthcare GmbH • Radiology • 03/05/2025

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Siemens Healthcare GmbH's Prostate MR AI (VA10A) is a radiological CADe/CADx software that employs AI to automatically segment the prostate gland, detect suspicious regions for cancer, and provide a PI-RADS interpretation suggestion from non-contrast T2-weighted and diffusion-weighted MRI series. This software functions as a concurrent reading aid, demonstrating in clinical studies a significant improvement in radiologists' diagnostic performance and interreader agreement for prostate cancer detection.

Summary

Siemens Healthcare GmbH's Prostate MR AI (VA10A) is a Radiological Computer Assisted Detection and Diagnosis (CADe/CADx) software. It is designed as a concurrent reading aid to assist radiologists in interpreting prostate MRI examinations for adult men aged 40 and older who are suspected of having cancer in treatment-naïve prostate glands. The software analyzes non-contrast T2-weighted (T2W) and diffusion-weighted image (DWI) series to automatically segment the prostate gland, detect and segment regions suspicious for cancer, and provide a lesion score, including a PI-RADS interpretation suggestion. The output also includes a suspicion map, but patient management decisions should not be made solely based on the algorithm's analysis. This software has been reviewed and determined to be substantially equivalent to a legally marketed predicate device. This determination is based on the software performing the same fundamental function and role in medical practice as the predicate. Comprehensive non-clinical testing was conducted, including automated prostate segmentation, lesion detection, and classification performance tests. A multi-reader multi-case clinical study further demonstrated that radiologists' diagnostic performance and interreader agreement significantly improved when aided by the software. The product adheres to relevant international standards and general control provisions, ensuring its safety and effectiveness for its intended use.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Prostate MRIAI softwareCADe/CADxCancer detectionT2-weighted imagingDiffusion-weighted imagingPI-RADSImage segmentationDiagnostic aidClinical validation

Device Metadata

Submission Number
K241770
Company
Siemens Healthcare GmbH
Panel
Radiology
Product Code
N/A
Data Type
N/A
Clinical Function
N/A
AI Function
N/A
AI Subclass
N/A

Relevant Clinical Questions

  • Q1. What is the quantitative breakdown of sensitivity, specificity, and accuracy for the AI's lesion detection and classification capabilities?; How adaptable is the AI software to different MRI scanner manufacturers, field strengths, and specific pulse sequences beyond standard T2W and DWI?; Are there specific types of prostate cancer lesions (e.g., small, multifocal, or those in difficult anatomical locations) where the AI performance is particularly strong or weak?; What post-market surveillance or continuous learning mechanisms are in place to ensure the software maintains or improves its performance over time with new data?; Beyond PI-RADS suggestions, does the software provide any additional quantitative metrics (e.g., lesion volume, ADC values) that could enhance diagnostic confidence or guide biopsy?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score20/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Prostate MR AI (VA10A) - Siemens Healthcare GmbH | ESL FDA AI Device Intelligence