Myomics
Phantomics Inc. • Radiology • 02/28/2025
Device Purpose
Myomics is an AI-powered software application designed for the qualitative and quantitative evaluation of cardiovascular magnetic resonance images. It employs semi-automated machine learning algorithms, rigorously validated against diverse datasets, to assist clinicians in assessing cardiac health and identifying lesions in adult patient populations.
Summary
Phantomics Inc. has received a determination that its device, Myomics, is substantially equivalent to existing legally marketed devices. Myomics is a software application intended for viewing, post-processing, and conducting qualitative and quantitative evaluations of cardiovascular magnetic resonance (MR) images in a DICOM standard format. It includes various tools, some of which are AI-powered, to assist physicians in assessing cardiac images, performing quantitative measurements of the heart and adjacent vessels, and identifying lesions, with semi-automated machine learning algorithms specifically designed for adult populations. This determination allows the company to market the device.The manufacturer is required to adhere to various ongoing regulatory provisions, including annual registration, device listing, good manufacturing practices, and labeling requirements. The device also underwent comprehensive performance testing, including bench tests comparing it to predicate devices, and software verification and validation in accordance with international standards. Furthermore, its integrated AI modules were rigorously validated using a large, diverse dataset from multiple MR imaging device vendors, with all modules meeting predefined performance acceptance criteria, affirming the device's safety and effectiveness for its intended use.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific performance metrics were used to validate the AI modules, and how did Myomics compare to human experts or other established methods?; Given its semi-automated nature, what is the required level of physician interaction or oversight for optimal diagnostic accuracy and reliability?; Are there any known limitations or contraindications for Myomics, particularly concerning specific cardiac conditions or patient demographics beyond adult populations?; How does Myomics integrate with existing hospital PACS systems and clinical workflows, and what are the data security measures in place for handling sensitive patient information?; Beyond the substantial equivalence determination, are there plans for post-market surveillance or further clinical trials to demonstrate long-term impact on patient outcomes?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly