Medscape Medical NewsAll articles

Brainomix 360 e-CTA

Brainomix Limited • Radiology • 01/06/2025

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Brainomix 360 e-CTA is a Class II medical image processing system that utilizes AI/ML algorithms to analyze CT Angiography datasets, specifically focusing on visualizing and quantifying vessel density asymmetry in the MCA region. Its development involved the integration of a novel 3D-colored overlay and was validated through digital phantom studies and a retrospective analysis of 308 brain scans, affirming its accuracy, safety, and efficacy for clinical use.

Summary

Brainomix Limited has developed the Brainomix 360 e-CTA, a Class II medical image management and processing system designed for use by trained medical professionals. This software system is intended for viewing, processing, and analyzing images obtained from DICOM-compliant imaging devices, specifically focusing on CT Angiography (CTA) datasets. Following a regulatory review, the device was deemed substantially equivalent to existing legally marketed systems, thereby making it available for clinical application under general regulatory provisions. The Brainomix 360 e-CTA's core functionality revolves around providing viewing and analysis capabilities for CTA, with a particular emphasis on identifying vessel density asymmetry within the Middle Cerebral Artery (MCA) region. Its technological foundation includes the integration of AI/ML algorithms to enhance image quality and improve vessel detection, along with features such as accessible posterior Maximum Intensity Projection (MIP) views and an innovative 3D-colored overlay for visualizing blood vessel density asymmetry. Performance was rigorously assessed through digital phantom validation and a retrospective study of 308 CTA brain scans, which collectively affirmed its accuracy in vessel and parenchyma delineation, overall effectiveness, and compliance with relevant risk management and cybersecurity standards, demonstrating both safety and efficacy.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Brainomix 360 e-CTACT AngiographyMedical ImagingAI/ML algorithmsVessel Density AsymmetryMCA regionDICOMImage ProcessingRetrospective StudyClinical Use

Device Metadata

Submission Number
K242123
Company
Brainomix Limited
Panel
Radiology
Product Code
N/A
Data Type
N/A
Clinical Function
N/A
AI Function
N/A
AI Subclass
N/A

Relevant Clinical Questions

  • Q1. How do the AI/ML algorithms specifically enhance image quality and vessel detection compared to traditional methods?; What is the sensitivity and specificity of the Brainomix 360 e-CTA in detecting subtle vessel density asymmetry in the MCA region compared to human expert assessment?; Beyond the MCA region, can the system's vessel density asymmetry analysis be applied effectively to other cerebral vascular territories?; What are the clinical workflow implications and time-saving benefits of integrating Brainomix 360 e-CTA into an acute stroke imaging protocol?; Are there ongoing or planned prospective studies to further validate the system's impact on patient outcomes or treatment decisions?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score25/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Brainomix 360 e-CTA - Brainomix Limited | ESL FDA AI Device Intelligence