CaRi-Plaque
Caristo Diagnostics Ltd. • Radiology • 02/20/2025
Device Purpose
The CaRi-Plaque is a web-based, non-invasive diagnostic software designed to analyze CT angiographic images for quantifying and characterizing coronary plaques and luminal stenoses. Its development involved extensive software verification and clinical validation demonstrating strong agreement with expert ground truth, thereby aiding healthcare professionals in determining treatment paths.
Summary
Caristo Diagnostics Ltd.'s CaRi-Plaque device, categorized as a medical image management and processing system, has achieved substantial equivalence to existing legally marketed devices, allowing its commercialization under applicable general controls and regulations. This regulatory milestone permits the company to market a non-invasive diagnostic tool intended for clinical use. The CaRi-Plaque is a web-based software designed to analyze Computed Tomography (CT) angiographic images, providing quantification and characterization of coronary plaques and luminal stenoses to assist healthcare professionals in treatment pathway determination. The finding of substantial equivalence was supported by rigorous software verification and validation, complemented by a clinical validation study that confirmed a high degree of agreement between the device's measurements and expert-derived ground truth for key diagnostic metrics, with results intended for use by trained operators alongside other clinical information and professional judgment.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific algorithms or methodologies does CaRi-Plaque utilize to quantify and characterize coronary plaques and luminal stenoses from CT angiographic images?; What were the exact metrics and statistical thresholds used to demonstrate 'strong agreement' between CaRi-Plaque measurements and expert-determined ground truth in the clinical validation study?; Beyond technical equivalence, what is the clinical utility or impact of CaRi-Plaque on patient management and outcomes compared to current diagnostic standards?; What are the specific requirements for 'trained operators' and what kind of training program does Caristo Diagnostics Ltd. provide for effective use of the device?; Are there any identified limitations or specific types of CT angiographic images (e.g., image quality, patient factors) where the CaRi-Plaque's performance may be compromised or less reliable?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly