OrthoNext Platform System
Orthofix Srl • Radiology • 12/19/2024
Device Purpose
The OrthoNext Platform System is a Class II medical image management and processing system designed to aid healthcare professionals in orthopedic preoperative and post-operative planning. It achieves this by allowing overlaying of product templates on radiological images, providing measurement tools, and integrating an AI/ML algorithm for automatic marker detection, with its substantial equivalence based on rigorous performance data and software validation.
Summary
The OrthoNext Platform System, developed by Orthofix Srl, has been determined to be substantially equivalent for its intended uses, enabling its market entry as a Class II medical image management and processing system. This system is engineered to support healthcare professionals in both preoperative planning for orthopedic surgical procedures and subsequent post-operative treatment planning. Its core functionality involves enabling the overlaying of product templates onto radiological images and offering tools for precise measurements and accurate template positioning, while emphasizing the critical role of clinical judgment in its application. This determination of substantial equivalence was substantiated through a comprehensive comparison with a legally marketed predicate device, addressing minor technological differences such as expanded post-operative planning capabilities and broader device compatibility, which were deemed not to raise new questions concerning safety or effectiveness. Performance data, including accuracy, sensitivity, and specificity for manual measurements, alongside the efficacy of an integrated AI/ML algorithm for automatic marker detection, were rigorously evaluated. Furthermore, extensive software verification and validation testing, adhering to international standards and relevant guidances, confirmed the system's functionality, safety, and usability, with continued marketing contingent upon ongoing adherence to regulatory requirements.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific types of orthopedic surgeries or conditions does the OrthoNext Platform System primarily support for preoperative and post-operative planning?; How does the integrated AI/ML algorithm's performance (accuracy, sensitivity, specificity) compare to human experts for automatic marker detection, particularly in complex or ambiguous cases?; Are there any long-term clinical studies or real-world data available that demonstrate the impact of using the OrthoNext Platform System on patient outcomes, surgical precision, or complication rates?; Given the system's "expanded device compatibility," what is the range of orthopedic products or implant manufacturers whose templates are supported, and how is this compatibility maintained or updated?; What are the specific data security and privacy measures implemented within the OrthoNext Platform System, especially considering it handles sensitive patient radiological images?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly