Medscape Medical NewsAll articles

syngo.via MI Workflows; Scenium; syngo MBF

Siemens Medical Solutions USA, Inc. • Radiology • 08/30/2024

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

The syngo.via MI Workflows, including Scenium and syngo MBF, is a software system designed for advanced post-processing and quantitative analysis of multi-modality medical images (PET, CT, MR, NM) to support clinical decision-making in oncology, cardiology, neurology, and radiotherapy planning. Its scientific advancement includes the integration of Centiloid scoring for standardized amyloid PET quantification in neurology, validated through calibration against reference datasets and demonstrating strong correlation with established methods and clinical assessments.

Summary

syngo.via MI Workflows, incorporating Scenium and syngo MBF applications, is a software-only medical device for multi-modality image post-processing. It assists trained healthcare professionals by enabling viewing, manipulation, quantification, analysis, and comparison of medical images from PET, CT, MR, and nuclear medicine, across single or multiple time-points. The system, operating on a client/server architecture, supports disease management in oncology, cardiology, neurology, and organ function, aids in radiotherapy treatment planning, and can perform SUV harmonization for PET data across different systems or reconstruction methods. A key enhancement in the latest version is the implementation of Centiloid scoring within the Scenium neurology application (VE70), designed to standardize brain PET amyloid quantification for Amyvid™, Neuraceq™, and Vizamyl™ tracers. This feature was validated by calibrating PET images against reference data, achieving high correlation (R² values of 0.95-0.98) with established methods. Independent validation further confirmed strong agreement with ADNI Centiloid values, and the Scenium Centiloid scale demonstrated excellent agreement with visual readings in classifying Mild Cognitive Impairment patients, with an optimal cut-off identified. Other components like syngo.MM Oncology, syngo.MI General, and syngo MBF cardiology (VB30) maintain their existing functionalities.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

syngo.via MI WorkflowsMedical Image ProcessingMulti-modality ImagingCentiloid ScoringAmyloid QuantificationSceniumsyngo MBFPET ImagingSUV HarmonizationRadiotherapy Planning

Device Metadata

Submission Number
K242275
Company
Siemens Medical Solutions USA, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the Centiloid scoring implementation in Scenium VE70 account for potential variations in image acquisition protocols or scanner calibrations across different clinical sites, beyond the three specifically validated tracers?; What is the clinical impact of the 26 Centiloid cut-off value in differentiating amyloid positivity, particularly in early or ambiguous cases of Mild Cognitive Impairment, and how does this compare to other quantitative amyloid PET analysis methods?; Could the SUV harmonization feature within syngo.via MI Workflows be extended to other radiotracers or quantitative metrics beyond PET SUV, and what are the validation requirements for such expansions?; Beyond the reported R-squared values, what were the specific limits of agreement or observed bias in the independent validation of Scenium's Centiloid scores against the ADNI pipeline for each of the three amyloid tracers?; How does the syngo.via MI Workflows platform handle and integrate longitudinal imaging data, especially for tracking disease progression or treatment response using the quantitative metrics it provides, such as Centiloid scores or harmonized SUVs?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(dataset, bias)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
syngo.via MI Workflows; Scenium; syngo MBF - Siemens Medical Solutions USA, Inc. | ESL FDA AI Device Intelligence