IQ-UIP
Imbio, Inc. • Radiology • 12/19/2024
Device Purpose
The IQ-UIP is a computer-aided radiology software designed to passively identify radiological findings suggestive of Usual Interstitial Pneumonia (UIP) in non-contrast adult chest CT scans. It utilizes an artificial intelligence algorithm trained and validated on anonymized multi-center CT data to generate informational reports, assisting specialists in detecting fibrotic lung disease patterns.
Summary
Imbio, Inc.'s radiology software, IQ-UIP, has been determined to be substantially equivalent to a legally marketed device for its stated indications for use. This classification allows the Class II device, regulated as radiology software for referral of findings related to fibrotic lung disease, to be marketed. The manufacturer is responsible for adhering to ongoing regulatory requirements, including annual registration, device listing, good manufacturing practices, proper labeling, and adherence to specific quality system controls. The IQ-UIP is a computer-aided software designed to passively notify specialists at interstitial lung disease centers of radiological findings suggestive of Usual Interstitial Pneumonia (UIP) in non-contrast adult chest CT scans. It uses an artificial intelligence algorithm to analyze images and generate informational summary reports on a dedicated worklist, separate from the standard imaging interpretation process. The device does not alter original medical images and is not intended for diagnostic purposes. Its development utilized anonymized, multi-center CT scan data, and its performance was validated through extensive testing, confirming its safety and effectiveness compared to a predicate device.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific features of CT scans does the AI algorithm prioritize or analyze to identify findings suggestive of UIP?; How does the performance of IQ-UIP compare to human expert interpretation in terms of sensitivity and specificity for detecting UIP-like patterns?; Given that the device is not for diagnostic purposes, how should clinicians integrate its "informational summary reports" into their diagnostic workflow without over-reliance?; What data sets were used for training and validation, and what was their demographic and disease severity distribution?; Are there plans to expand the capabilities of IQ-UIP to other interstitial lung diseases or to integrate it more directly into standard PACS systems?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly