Device Purpose

The ScanDiags Ortho L-Spine MR-Q software aims to provide quantitative measurements of lumbar spine anatomical structures from pre-acquired MR images. It achieves this through semi-automatic segmentation driven by deep convolutional neural networks, demonstrating robust accuracy and reliability for clinical review and analysis.

Summary

ScanDiags AG's Ortho L-Spine MR-Q software, a cleared medical image management and processing system, serves to provide quantitative spine measurements from pre-acquired lumbar spine Magnetic Resonance (MR) images. Its primary function is to assist users in hospitals and medical institutions by visualizing and documenting precise area and distance measurements of critical lumbar spine anatomical structures, including vertebral bodies, intervertebral discs, neuroforamina, and thecal sacs, for subsequent review, analysis, and interpretation. This software-as-a-medical-device (SaMD) utilizes semi-automatic segmentation powered by deep convolutional neural networks (DCNN) to process standard DICOM MRI images, subsequently generating a comprehensive PDF report of these measurements. While it functions as a valuable adjunct tool, it is explicitly designed not to produce medical diagnoses or supersede clinical judgment. Performance evaluations, notably a retrospective multicenter study, validated its robust accuracy in measurements and segmentations, demonstrating high Intraclass Correlation Coefficients (ICC) and Dice Similarity Coefficients (DSC) across various spinal structures, thereby affirming its consistency and reliability.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

ScanDiags Ortho L-Spine MR-QLumbar spineQuantitative measurementsMagnetic Resonance Imaging (MRI)Deep Convolutional Neural Networks (DCNN)Semi-automatic segmentationMedical image managementDICOMMeasurement accuracyClinical support tool

Device Metadata

Submission Number
K242607
Company
ScanDiags AG
Panel
Radiology
Product Code
N/A
Data Type
N/A
Clinical Function
N/A
AI Function
N/A
AI Subclass
N/A

Relevant Clinical Questions

  • Q1. What specific DCNN architectures were employed and how were they trained and validated to ensure robustness across diverse patient populations and MRI scanner types?; How does the software handle image artifacts or variations in image quality, and what are the limitations or potential sources of error in its semi-automatic segmentation process?; Are there plans for prospective clinical trials to evaluate the software's impact on clinical workflow efficiency, diagnostic confidence, or patient outcomes?; How does the software's performance compare to manual measurements by expert clinicians, and what is the inter-observer and intra-observer variability when using the tool?; Beyond the stated structures, what is the potential for expanding the software's capabilities to measure other spinal pathologies or to integrate with other imaging modalities?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Qualifies as a cyber device under §524B (post-Dec 2023, networked)

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(neural network)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
ScanDiags Ortho L-Spine MR-Q - ScanDiags AG | ESL FDA AI Device Intelligence