Device Purpose

QP-Prostate® CAD is an AI-based image processing software designed for Computed Aided Detection and Diagnosis (CADe/CADx) of suspected prostate lesions using bi-parametric prostate MRI. It employs artificial intelligence to automatically identify and mark lesions, enhancing clinical reader performance in identifying clinically significant prostate cancer, and has demonstrated substantial equivalence to a predicate device through comprehensive performance assessments.

Summary

Quibim S.L. has developed QP-Prostate® CAD, an artificial intelligence-based image processing software designed for Computed Aided Detection and Diagnosis (CADe/CADx). This software automatically identifies and marks suspected lesions within the prostate gland using bi-parametric prostate MRI, indicating different levels of suspicion. It is intended for use by trained physicians, such as radiologists and urologists, as a concurrent aid in interpreting prostate MRI studies for patients over 40 years old, with results displayable on standard medical imaging systems. The QP-Prostate® CAD device is categorized as Class II radiological computer assisted detection/diagnosis software. It was found to be substantially equivalent to a legally marketed predicate device, ProstatIDTM, sharing similar intended uses, indications, and technological characteristics. While there are minor differences in their underlying AI algorithms and how suspicions are presented, comprehensive performance assessments, including standalone and multi-reader multi-case studies, confirmed that these differences do not raise new questions of safety or effectiveness. The studies demonstrated that the device functions as intended, enhancing clinical reader performance in identifying clinically significant prostate cancer, thus establishing its safety and effectiveness.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

QP-Prostate® CADArtificial intelligenceImage processing softwareProstate MRIComputed Aided DetectionComputed Aided DiagnosisProstate cancerClinical reader performanceSubstantial equivalenceMedical imaging systems

Device Metadata

Submission Number
K242683
Company
Quibim S.L.
Panel
Radiology
Product Code
N/A
Data Type
N/A
Clinical Function
N/A
AI Function
N/A
AI Subclass
N/A

Relevant Clinical Questions

  • Q1. How does the AI algorithm in QP-Prostate® CAD specifically differ from ProstatIDTM, and what are the clinical implications of these differences?; What were the specific metrics used in the standalone and multi-reader multi-case studies to assess safety and effectiveness, particularly regarding false positives/negatives?; Are there specific MRI sequences or parameters that optimize the performance of QP-Prostate® CAD?; What is the long-term impact of using QP-Prostate® CAD on biopsy rates, overdiagnosis, and patient outcomes in a clinical setting?; Could QP-Prostate® CAD be adapted or integrated with other imaging modalities beyond bi-parametric prostate MRI for prostate cancer detection?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.