cvi42 Software Application
Circle Cardiovascular Imaging Inc. • Radiology • 10/15/2024
Device Purpose
The cvi42 Software Application serves as a medical device for qualified professionals to perform quantitative evaluation and post-processing of cardiovascular MR and CT images. Its scientific foundation lies in integrating digital image processing with machine learning techniques to enable semi-automatic contouring and comprehensive cardiac measurements, thereby supporting diagnostic analysis and clinical decision-making.
Summary
The cvi42 Software Application, developed by Circle Cardiovascular Imaging Inc., is designed for qualified medical professionals to view, post-process, and quantitatively evaluate cardiovascular magnetic resonance (MR) and computed tomography (CT) images. This software functions as a medical device, providing digital image processing, visualization, quantification, and reporting tools to support physicians in the evaluation and analysis of cardiovascular imaging studies. It is specifically intended for use with cardiac images acquired from MR or CT scanners.The software offers comprehensive measurement capabilities, including distance, area, volume, mass, signal intensity, Agatston score, and various cardiac function and strain parameters. It integrates machine learning techniques for semi-automatic contouring of regions of interest, with these algorithms trained and tested on anonymized datasets from multiple clinical sites. Performance testing has confirmed the software's compliance with specified design requirements and standards, validating both its traditional and machine learning functionalities, and supporting its safety and effectiveness for its defined use.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What is the demonstrated impact of cvi42's machine learning algorithms on diagnostic accuracy and workflow efficiency compared to manual methods or other software?; How robust is the cvi42 software's performance across diverse patient populations, different scanner manufacturers, and varying image acquisition protocols?; Are there specific cardiac pathologies or complex anatomical variations where the semi-automatic contouring exhibits limitations or requires significant manual correction?; What specific clinical endpoints or outcomes have been or will be investigated to demonstrate the clinical utility and improved patient care facilitated by using cvi42?; Beyond basic measurements, what advanced functionalities or unique insights does cvi42 provide that differentiate it from competing cardiovascular imaging software?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.