LensHooke X3 PRO Semen Quality Analyzer; LensHooke X3 PRO SE Semen Quality Analyzer
Bonraybio Co., LTD. • Hematology • 05/30/2025
Device Purpose
The LensHooke X3 PRO and X3 PRO SE are optical devices designed for automated human semen analysis, providing quantitative measurements of key sperm parameters for both professional and home-use settings. These devices leverage optical design, image analysis, and artificial intelligence to achieve substantial equivalence to predicate devices, offering an efficient method for assessing semen quality, though not a comprehensive fertility diagnosis.
Summary
Bonraybio Co., LTD. has received regulatory approval for its LensHooke X3 PRO and LensHooke X3 PRO SE Semen Quality Analyzers, with a determination of substantial equivalence to previously marketed predicate devices. These optical devices are designed for human semen analysis, providing automated, quantitative measurements of critical parameters including sperm concentration, total motility (progressive, non-progressive, and immotility), sperm morphology (normal forms), and pH value. This clearance permits the marketing of the devices, provided they adhere to standard regulatory controls such as annual registration, device listing, good manufacturing practices, and truthful labeling. Both models employ optical design, image analysis, and artificial intelligence to perform automated semen quality assessments. The LensHooke X3 PRO model is specifically intended for use in professional healthcare settings, such as clinical laboratories and point-of-care facilities, while the LensHooke X3 PRO SE is designed for over-the-counter use by individuals in a home setting. The substantial equivalence determination was based on comprehensive non-clinical and clinical performance evaluations, including accuracy and user performance studies, comparing the new analyzers against the existing LensHooke X1 PRO and X1 PRO SE Semen Quality Analyzers. It is important to note that neither device offers a comprehensive evaluation of a male’s fertility status.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. Given the "substantial equivalence" determination, what are the specific performance differences, if any, between the X3 PRO/SE and the X1 PRO/SE models, particularly regarding accuracy in diverse clinical samples?; How does the AI-driven image analysis account for inter-sample variability and potential artifacts, and what is its sensitivity and specificity in detecting subtle morphological abnormalities?; For the over-the-counter LensHooke X3 PRO SE, what specific user performance studies were conducted to ensure accurate and reliable results by lay users in a home environment?; Since the devices do not provide a "comprehensive evaluation of a male’s fertility status," what additional diagnostic parameters or follow-up tests are recommended for individuals with abnormal results from these analyzers?; What are the long-term data on the reproducibility and reliability of the automated pH measurement, and how critical is its accuracy for clinical interpretation of semen quality?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, OBOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly