uMR Omega
Shanghai United Imaging Healthcare Co., Ltd. • Radiology • 05/21/2025
Device Purpose
The uMR Omega is a Class II magnetic resonance diagnostic imaging system designed to produce detailed visual information of internal anatomical structures and functions through advanced imaging and spectroscopic capabilities. Its science relies on magnetic fields and radiofrequency pulses, with recent modifications focusing on enhanced RF coils, pulse sequences, and sophisticated image processing and reconstruction methods to improve diagnostic utility and workflow efficiency.
Summary
The uMR Omega diagnostic imaging system, manufactured by Shanghai United Imaging Healthcare Co., Ltd., has been determined to be substantially equivalent to previously marketed devices. This Class II magnetic resonance diagnostic device is designed to produce sagittal, transverse, coronal, oblique cross-sectional, and spectroscopic images. These images provide visual information about the internal anatomical structure and/or function of the head, body, and extremities, which can be interpreted by a trained physician to assist in diagnosis. This version of the uMR Omega incorporates several modifications, including the addition of new RF coils, updated dimensions for the detachable patient table, and enhancements to pulse sequences. It also features new imaging processing methods such as Inline Cardiac function, Inline ECV, and Inline MOCO, as well as new workflow features like Breast Biopsy and EasyFACT. New image reconstruction methods, including SparkCo, have also been added. Comprehensive non-clinical testing was performed, encompassing surface heating, image performance, and adherence to various safety, electromagnetic compatibility, software, and biocompatibility standards, confirming that the changes do not impact the device's intended use, fundamental technology, safety, or effectiveness.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific clinical advantages do the new Inline Cardiac function, Inline ECV, and Inline MOCO imaging processing methods offer compared to previous versions or competing systems?; How do the new RF coils and enhanced pulse sequences specifically improve image quality or reduce scan times for various anatomical regions?; What were the quantitative results of the non-clinical image performance testing, particularly regarding resolution, signal-to-noise ratio, and contrast for challenging pathologies?; Could the SparkCo image reconstruction method lead to a significant reduction in acquisition time or improved image fidelity, especially for specific clinical applications?; What training or workflow adjustments are required for clinicians to effectively utilize the new Breast Biopsy and EasyFACT features, and what is their impact on diagnostic efficiency?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, ML-BOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.