Brainomix 360 e-ASPECTS
Brainomix Limited • Radiology • 02/14/2025
Device Purpose
The Brainomix 360 e-ASPECTS is a Class II radiological computer-assisted diagnostic software that utilizes artificial intelligence to process non-contrast CT brain images, generating an Alberta Stroke Program Early CT (ASPECTS) score to assist medical imaging professionals in characterizing ischemic brain tissue injury. Its purpose is to enhance diagnostic accuracy for clinicians evaluating the extent of disease within 24 hours of a patient's last known well time, as demonstrated by improved reader performance in clinical studies.
Summary
Brainomix 360 e-ASPECTS is a Class II radiological computer-assisted diagnostic software, now cleared for market distribution, that assists clinicians in the evaluation of brain tissue abnormalities. Designed for medical imaging professionals, its core purpose is to characterize ischemic brain tissue injury and assess the extent of disease within 24 hours of a patient's last known well time, by processing non-contrast CT brain images. The device's market entry is underpinned by its determination of substantial equivalence to existing legally marketed devices and adherence to standard regulatory controls, including good manufacturing practices and proper labeling. The scientific foundation of Brainomix 360 e-ASPECTS lies in its utilization of artificial intelligence to automatically generate an Alberta Stroke Program Early CT (ASPECTS) score from these CT scans. This AI-driven methodology encompasses automated image registration, segmentation, and detailed analysis of ASPECTS regions, augmented by visualizations of contributing voxels and volume calculations, thereby enhancing diagnostic precision. Clinical performance studies have substantiated the software's ability to improve reader accuracy, and recent modifications, such as an extended time window for use and adjusted patient selection criteria, have been validated to ensure no new safety or effectiveness concerns arise compared to predicate devices.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the AI algorithm within Brainomix 360 e-ASPECTS specifically improve upon human interpretation of ASPECTS scores, particularly in subtle or ambiguous cases?; What was the design of the clinical performance studies that demonstrated improved reader accuracy, and what were the specific metrics used to quantify this improvement?; Are there any specific limitations or edge cases where the Brainomix 360 e-ASPECTS software might provide inaccurate or misleading ASPECTS scores, and how are these mitigated?; How does the extended 24-hour time window for use impact the diagnostic utility and clinical decision-making compared to shorter timeframes, and what evidence supports its safety and effectiveness in this broader window?; Beyond ASPECTS scoring, does the software provide any additional prognostic or therapeutic guidance based on the identified ischemic changes, or is it purely a diagnostic aid?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly