Medscape Medical NewsAll articles

Synapse 3D Base Tools (V7.0)

FUJIFILM Corporation • Radiology • 05/21/2025

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

The Synapse 3D Base Tools (V7.0) is a Class II medical imaging software designed to assist trained professionals in comprehensive image interpretation and treatment planning, processing DICOM-compliant images from various modalities. Its scientific basis lies in advanced algorithms for 2D/3D visualization, multi-planar reconstruction, image fusion, and segmentation, providing specialized analysis features for anatomical structures, supported by performance testing for substantial equivalence.

Summary

The Synapse 3D Base Tools (V7.0), developed by FUJIFILM Corporation, received a substantial equivalence determination from the U.S. Food & Drug Administration on May 21, 2025, classifying it as a Class II medical image management and processing system. This regulatory clearance permits its marketing, subject to standard controls such as annual registration, device listing, and adherence to good manufacturing practices, indicating its readiness for clinical use. Its determination of substantial equivalence was supported by performance testing, including data from US patient populations, and compliance with safety and cybersecurity standards. The software is designed for trained medical professionals to assist in reading, interpreting, reporting, and treatment planning across various medical imaging modalities like CT, MR, and US, specifically excluding primary diagnostic interpretation for mammography. Its functionality includes 2D and 3D viewing, multi-planar reconstructions, image fusion, and segmentation, incorporating new features such as Pancreas Analysis, Rectal Analysis, and a Segmentation Viewer.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Synapse 3D Base ToolsFUJIFILM CorporationMedical imaging softwareFDA clearanceSubstantial equivalenceDICOM-compliantVolume renderingImage segmentationTreatment planningClass II medical device

Device Metadata

Submission Number
K243762
Company
FUJIFILM Corporation
Panel
Radiology
Product Code
N/A
Data Type
N/A
Clinical Function
N/A
AI Function
N/A
AI Subclass
N/A

Relevant Clinical Questions

  • Q1. What specific improvements or novel methodologies in V7.0 led to the new Pancreas Analysis and Rectal Analysis features, and how do they enhance diagnostic accuracy or treatment planning compared to previous versions or competing systems?; While substantial equivalence was determined, what were the specific performance metrics and validation studies, including quantitative results from US patient populations, that demonstrated its safety, efficacy, and accuracy for different imaging modalities?; How does the Synapse 3D Base Tools (V7.0) integrate with existing hospital PACS systems and electronic health records, and what are its capabilities for data sharing and interoperability in a multi-vendor clinical environment?; Beyond the stated exclusion for mammography, are there other imaging contexts or disease states where the software's use is contraindicated or where its performance has known limitations?; What are the long-term support plans, including software updates, cybersecurity protocols, and training programs, that FUJIFILM Corporation will provide to ensure the sustained safe and effective use of Synapse 3D Base Tools (V7.0) in clinical settings?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score45/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(environment)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, OBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Synapse 3D Base Tools (V7.0) - FUJIFILM Corporation | ESL FDA AI Device Intelligence