Medscape Medical NewsAll articles

QFR (3.0)

QFR Solutions bv • Radiology • 04/04/2025

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

The QFR (3.0) is a standalone software package engineered to provide validated and reproducible quantitative assessment of coronary vessels and lesion quantification in patients with coronary artery disease. This is achieved by leveraging deep learning models for accurate 3D reconstruction from 2D angiographic projections, thereby supporting precise clinical decision-making for interventional cardiologists.

Summary

A review of the QFR (3.0) device has determined it to be substantially equivalent to other legally marketed devices for its specified clinical applications. This allows the device, an angiographic X-ray system, to be marketed. The QFR (3.0) is intended for use in clinical settings where validated and reproducible quantitative results are necessary to support the assessment of coronary vessels in X-ray angiographic images of individual patients with coronary artery disease, with results intended for use by responsible clinicians.The QFR (3.0) is a standalone software package designed for interventional cardiologists and researchers to obtain quantifications of lesions in coronary vessels. It functions by calculating a QFR value based on a 3D reconstruction derived from 2D angiographic projections, utilizing deep learning models to assist in steps such as vessel selection, contour detection, and determination of specific image frames for analysis. Performance evaluations indicate that these algorithmic improvements meet defined acceptance criteria, while still allowing users to review and correct results. The device shares the same intended use and indications for use as its predicate device, and non-clinical and clinical performance data affirm its comparable performance and safety.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

QFR (3.0)Coronary artery diseaseAngiographic X-rayDeep learningLesion quantification3D reconstructionQuantitative flow ratioInterventional cardiologyVessel assessmentClinical validation

Device Metadata

Submission Number
K243769
Company
QFR Solutions bv
Panel
Radiology
Product Code
N/A
Data Type
N/A
Clinical Function
N/A
AI Function
N/A
AI Subclass
N/A

Relevant Clinical Questions

  • Q1. How does the QFR (3.0)'s deep learning model specifically improve the accuracy and reproducibility of vessel contour detection and QFR value calculation compared to its predicate device?; What are the validated clinical outcomes or benefits observed when QFR (3.0) is used to guide treatment decisions in patients with coronary artery disease, beyond simply providing quantitative results?; Can the QFR (3.0) effectively quantify lesions in complex coronary anatomies or in the presence of calcification, and what are the limitations in such challenging cases?; What is the required expertise or training for clinicians to effectively utilize and interpret the QFR (3.0) results, especially given the allowance for user review and correction?; Are there ongoing or planned studies to compare the diagnostic accuracy and clinical utility of QFR (3.0) against other established physiological assessment methods like FFR or iFR invasively?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence✓ Detected in Summary
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials(software package)
✓ Detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SBOM, ML-BOM detected in AI-generated device summary.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
QFR (3.0) - QFR Solutions bv | ESL FDA AI Device Intelligence