Medscape Medical NewsAll articles

Clarius Prostate AI

Clarius Mobile Health Corp. • Radiology • 04/16/2025

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Clarius Prostate AI is a Class II Medical Image Management and Processing System designed for semi-automatic prostate volume measurement using ultrasound data, aiming to enhance clinical efficiency and accuracy. Its science relies on a machine learning algorithm validated through non-clinical and clinical studies demonstrating non-inferiority to manual expert measurements, with future modifications managed under a Predetermined Change Control Plan.

Summary

Clarius Mobile Health Corp.'s device, Clarius Prostate AI, has been found substantially equivalent to legally marketed devices for its intended use. This device, classified as a Medical Image Management and Processing System (Class II), is designed for semi-automatic measurements of prostate volume based on ultrasound data acquired by Clarius Ultrasound Scanners. The determination allows the device to be marketed, subject to general controls including annual registration, device listing, good manufacturing practice, and labeling requirements. The device's safety and effectiveness were affirmed through comprehensive non-clinical and clinical performance testing. Clinical studies demonstrated that Clarius Prostate AI's automated measurements were non-inferior to manual measurements performed by qualified experts, exhibiting high accuracy and meeting user needs. Future modifications to the device's machine learning algorithm will adhere to a Predetermined Change Control Plan, ensuring continued safety and effectiveness. Manufacturers must also comply with various ongoing requirements such as the Quality System regulation, medical device reporting, labeling, and unique device identification rules.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Clarius Prostate AIProstate volumeUltrasound dataSemi-automatic measurementsMedical Image Management and Processing SystemSubstantial equivalenceClinical studiesMachine learning algorithmPredetermined Change Control PlanRegulatory compliance

Device Metadata

Submission Number
K243853
Company
Clarius Mobile Health Corp.
Panel
Radiology
Product Code
N/A
Data Type
N/A
Clinical Function
N/A
AI Function
N/A
AI Subclass
N/A

Relevant Clinical Questions

  • Q1. How does the specific machine learning algorithm used by Clarius Prostate AI compare in efficiency and accuracy to other AI-based prostate volume measurement systems?; What are the specific parameters or metrics used to define "non-inferiority" in the clinical studies, and what was the observed variability between automated and manual measurements?; Beyond prostate volume, could the Clarius Prostate AI be expanded to assist with other prostate imaging tasks or diagnostic features?; What is the long-term plan for validating the continued accuracy and safety of the device's machine learning algorithm under the Predetermined Change Control Plan, especially with real-world data drift?; What impact does the integration of Clarius Prostate AI have on clinical workflow and diagnostic throughput compared to traditional manual measurement methods?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score20/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, drift, labeling)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Clarius Prostate AI - Clarius Mobile Health Corp. | ESL FDA AI Device Intelligence