Clarius Median Nerve AI
Clarius Mobile Health Corp. • Radiology • 05/08/2025
Device Purpose
The Clarius Median Nerve AI device is an assistive medical image processing system that uses a machine learning algorithm to perform semi-automatic, non-invasive measurement of the median nerve cross-sectional area from ultrasound data. Its purpose is to aid healthcare professionals by providing accurate measurements demonstrated to be non-inferior to manual expert measurements, thereby enhancing diagnostic workflows for conditions like carpal tunnel syndrome.
Summary
Clarius Mobile Health Corp.'s Clarius Median Nerve AI device has achieved substantial equivalence to a legally marketed predicate device, classifying it as a Class II medical image management and processing system. Its primary function is the segmentation and semi-automatic non-invasive measurement of the median nerve cross-sectional area using ultrasound data from Clarius Ultrasound Scanners. This assistive tool is intended for use by healthcare professionals trained in ultrasound on adult patients, with the user ultimately responsible for validating measurements based on clinical judgment. The device is subject to standard general controls, including annual registration, device listing, good manufacturing practices, and truthful labeling. The Clarius Median Nerve AI is integrated into the Clarius App software, leveraging a machine learning algorithm for automated detection, segmentation, and measurement. Its safety and effectiveness were rigorously established through comprehensive non-clinical and clinical performance testing, encompassing software verification and validation activities. A retrospective clinical verification study demonstrated that the device's automated measurements were non-inferior to those performed manually by human experts, exhibiting strong agreement. Furthermore, a clinical validation study confirmed the device's intended performance and its ability to meet user needs in a simulated environment. A Predetermined Change Control Plan (PCCP) has also been implemented to manage future modifications to the device's AI model, ensuring continued safety and effectiveness without requiring new premarket reviews if changes adhere to the plan.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific clinical conditions or patient demographics were included in the retrospective and validation studies, and how might these influence the device's applicability across diverse populations?; Beyond "strong agreement," what were the actual statistical metrics (e.g., Bland-Altman limits of agreement, intraclass correlation coefficient) demonstrating non-inferiority to manual measurements?; How does the Clarius Median Nerve AI device account for potential inter-operator variability in ultrasound probe placement or image acquisition, and what impact does this have on measurement consistency?; What are the criteria and review processes outlined in the Predetermined Change Control Plan (PCCP) to ensure ongoing safety and effectiveness for future AI model modifications?; Could the device's AI model be trained or adapted for other nerve measurements or pathologies, and what would be the regulatory pathway for such expansions?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, OBOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.